19.6 Appliances with PTC heating elements are supplied at rated voltage until steady conditions with regard to power input and temperature are established.The working voltage of the PTC heating element is increased by 5 % and the appliance is operated until steady conditions are re-established. The voltage is then increased in similar steps until 1,5 times working voltage is reached, or until the PTC heating element ruptures, whichever occurs first.