The dimension requirement of chamfering at the interface of valve body is not indicated on the product drawing of solenoid valve;<br>As a result, the sealing ring provided by sealing plug cover and fast connection - peg does not match with the valve body interface (the chamfering size at the valve body interface is too large), and the sealing ring does not work (according to the drawing requirements, the seal ring diameter is φ 2, and the seal ring size is qualified).<br>