The composition of the ingoing gas mixture, outgoing gaseous atmosphere and the nitriding potential for each stage of the process shall be automatically controlled, maintained and recorded (see 4.3). Devices for accurate control of flow rates of the individual gases shall operate automatically in response to signals from the atmosphere analyzer.