Towers and spires when enclosed shall have exterior walls as required for the building to which they are attached. Towers not enclosed and which extend more than 20.00 meters above the grade shall have their framework constructed of iron, steel, or reinforced concrete. No tower or spire shall occupy more than one-fourth (1/4) of the street frontage of any building to which it is attached and in no case shall the base area exceed 150.00 sq. meters unless it conforms entirely to the type of construction requirements of the building to which it is attached and is limited in height as a main part of the building. If the area of the tower and spire exceeds 10.00 sq. meters on any horizontal cross section, its supporting frames shall extend directly to the ground. The roof covering of the spires shall be as required for the main room of the rest of the structure. Skeleton towers used as radio masts, neon signs, or advertisement frames and placed on the roof of any building shall be constructed entirely of incombustible materials when more than 7.50 meters in height, and shall be directly supported on an incombustible framework to the ground. No such skeleton towers shall be supported on roofs of combustible framings. They shall be designed to withstand a wind load from any direction in addition to any other loads