6.2 ESD RatingsVALUE UNITV(ESD) Electrostatic dischargeHuman-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000VCharged-device model (CDM), per JEDEC specification JESD22-C101(2) ±1500(1) For more information about VCXO configuration, and crystal recommendation, see application report VCXO Application Guideline forCDCE(L)9xx Family (SCAA085).(2) Pulling range depends on crystal type, on-chip crystal load capacitance, and PCB stray capacitance; pulling range of minimum ±120ppm applies for crystal listed in the application report VCXO Application Guideline for CDCE(L)9xx Family (SCAA085).