Speed set-point for each drive is created in PLC. Considering the actual diameter of therolls, the gear ratio and over-speeds where is necessary, the linear speed inserted byoperator in L1-HMI is converted in angular speed, what is reference speed for drive( see“Speed set-point” figure ).