For class II appliances, capacitors shall not be connected to accessible metal parts and their casings, if of metal, shall be separated from accessible metal parts by supplementary insulation.This requirement does not apply to capacitors complying with the requirements for protective impedance specified in 22.42.Compliance is checked by inspection and by the relevant tests.