The speed controller uses the proportional integral control mode. The main speed setting value is set according to the set speed value of the set point generator. It acts as the set value of the speed controller together with the additional speed setting value output by the position controller. The actual analog input value of the speed controller is the analog input value input by the speed encoder, and the output value of the speed controller will be used as the reference for the torque setting value.