7.5.3 ProcedureThe test shall be carried out as follows:— Mount the test sample onto the headform and adjust for a secure fit, or in accordance with the information supplied by the manufacturer, if provided.— With the test sample in place on the headform, probe all openings in the test sample with the rod in an attempt to reach, without appreciable force, the area to be protected of the headform. If the rod, without moving the test sample, can touch the area to be protected of the headform, a potential path for approaching projectiles is indicated, and the test sample shall be considered to not meet the requirement. A point of contact by the rod on the edge of the area to be protected on the headform shall be considered a failure to meet the requirement.7.5.4 Test reportReport whether or not the rod touched the area to be protected of the headform.