Several laboratory test methods are being commonly used for determining the chloride diffusion coefficient. The bulk immersion tests, described e.g. in NT Build 443 [3] or ASTM C1556–03 [4], are long term diffusion tests in which concrete samples are exposed to a chloride solution for a relatively long period of time.