ANCHOR BOLTS AND EMBEDDED ITEMS SHALL BE SET ACCURATELY, USING TEMPLATES WITHIN THE
TOLERANCES SPECIFIED IN AISC 303-10 SECTION 7.5, CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES UNLESS MORE PRECISE PLACEMENT IS SPECIFIED ON DESIGN / VENDOR SHOP DRAWINGS. THE
BOTTOM OF ANCHOR BOLTS SHALL BE SECURED TO PREVENT MOVEMENT OR TILTING OF THE ANCHOR
BOLTS DURING CONCRETE PLACEMENT. THE OVERSIZED HOLES USED IN STRUCTURAL STEEL BASE PLATES
ARE SIZED TO ACCOMMODATE ANCHOR BOLTS THAT ARE SET WITHIN THE TOLERANCES SPECIFIED ABOVE.