In order to meet lighting requirements, it is necessary for the manufacturer to define the term “adequate.” It is defined as the amount of light (lux or foot-candles) reaching the working surface for each area involved in the production of pharmaceuticals. Public standards exist for some types of work. Normally, a range of 30–50 foot-candles ensure worker comfort and ability to perform efficiently and effectively; however, 100 foot-candles may be needed in some areas, as well as special lighting for some operations, such as inspection of filled vials. Once the light levels have been defined, it is necessary that they be measured periodically and the results recorded. The specifications should call either for replacement of light sources when some level above the established minimum has been reached or, alternatively, routine replacements of light sources on some schedule that has been shown adequate to ensure that light levels do not drop below the established minimum.