— The SCH procedure at the different temperatures shall follow 6.2.2.3.1.— The SC procedure shall follow 6.2.— All discharge tests shall be terminated at the supplier's discharge voltage limits. NOTE The SCH for top off enables the recharging of the DUT in order to compensate for energy losses that can occur during temperature equilibration. 7.3.3.2 High-energy battery pack and system The test shall be performed at six different temperatures (40 °C, RT, 0 °C, −10 °C, −18 °C and −25 °C) and shall cover a SOC range of 90 % to 20 % within five steps (90 %, 70 %, 50 %, 35 %, 20 %) whereas the last step at 20 % SOC shall only be performed if the maximum discharge current of the DUT is equal to or less than a 5C current rate in order to avoid a deep discharge of the DUT.