EDXA of the solid state powder ceramic (Fig. 4h) indicates that, as with the nanopowder ceramic, there are no detectable levels of chlorine le in the ceramic aer the post-press heating. This is in contrast to the ceramic examined before the heating step (Fig. S4†) showing high levels of chorine present in EDXA.