Increasing the inspections and sample sizes is not avoiding the deviation. Not only the thread, as well the peaks are defective. b) Certificates 3.1 acc. EN10204: Not the latest standards (ISO 3269) are in use and no single values given (e.g. tensile strength). Hardness and torque tests should be done.c) Please check the standard management in general and as well the supplier management.