Thermal-overload protection limits total power dissipation in the AT1605. When the junction temperature exceeds Tj=130°C, a thermal sensor activates the thermal protection, which shuts down the IC, allowing the IC to cool. Once the device cools down by 20°C, IC will automatically recover normal operation. For continuous operation, do not exceed the absolute maximum junction-temperature rating of Tj=150°C.