In the lubricated condition, the hydrodynamic load sup-porting film has to be taken into account. With theexception of the QPQ® treated samples, there is moresolid mass because of the surface roughness so that theresults presumably lie within the mixed friction range.Under these test conditions, of all variants the QPQ®nitrocarburized samples had the lowest friction coeffi-cient.