A fully discharged DUT (i.e. discharged to the manufacturer’s specified EODV) is to be subjected to an overcharge resulting from a single fault condition in the charging protection/control circuit of the system that could lead to an overcharge condition. See Section 9 for a description of a single fault condition. Single fault conditions can be applied to both passive and active protective devices. The test supply equipment used for charging the DUT shall be sufficient to create an overcharge of the DUT to at least 110% of the maximum specified charging voltage. The charging rate used shall be the manufacturer’s specified maximum charging rate