For both RK and SCC, the brick expansions in the circular direction were not calculated. The expansion of the circular brick ring could induce an important tension on the outer shell. If it was not correctly managed, it could damage the kiln/furnace outer shell. Additional thermo-mechanical calculation of outer shell strength is needed, if the expansion is too important.