During the flexing test, there shall be- no interruption of the current;- no short-circuit between conductors.Note 2 A short-circuit between the conductors of the flexible cable or cords is considered to occur if the current attains a value equal to twice the test current of the IC-CPD.The voltage drop between each contact and the corresponding conductor loaded with the test current shall not increase by more than 10mv.After the test guard, if any, shall not have become separated from the body and the insulation of the flexible cable or cord shall show no sign of abrasion or wear. Broken strands of the conductor shall not have pierced the insulation so as to become accessible.Note 3 The revision of this test is under consideration.