Finish Color6.9.2.1 Sample Size: refer 6.2 sampling plan6.9.2.2 Check environment: (1) Working Floor: 75-100 Foot Candles (2) Light Booth: (CWF: 4150k)6.9.2.3 Color/Gloss/Texture(highlighting): please check with Moen master samples, parts must in min and max range, if close to min or max limit, Acceptable but must improve next lot 6.9.2.4 Color Match: the whole set product each component color can not have big difference, if have big difference but all in range, Acceptable but must improve next lot6.9.2.5 Detailed please refer 7.4 “Finish color WI”6.9.3 Finish Performance6.9.3.1 Corrosion Test: (1) Sampling sizei. Supplier: need test for each lot and at least 3pcs for each part each finish each production lot, Moen SQE need check supplier Test reportj. Moen Quality test sampling Size: please follow up “ AASS Test control plan”(2) Test Method and judgment: please refer 7.5 “ES-160 standard” for different requirement