Visual and dimensional inspections:EIA 364-18Visual, dimensional, and functional per applicable quality inspection planMeets product drawing requirementsInsertion force:EIA 364-13Measure the force necessary to mate the connector assemblies at a maximum rate of 12.5 mm (0.492 inches) per minute, using a steel gauge 1.70 mm thick with a tolerance + 0.00, - .01 mm1.15 N maximum per contact pair Removal force:EIA 364-13Measure the force necessary to unmate the connector assemblies at maximum rate of 12.5 mm (0.492 inches) per minute, using a steel gauge 1.44 mm thick with a tolerance + .01, - 0.00 mm0.15 N minimum per contact pair