The resistance value should be selected to maximize the input bandwidth use of the coulombcounter range, CCRANGE, but not exceed the absolute maximum ratings.• Using the normal max discharge current, RSNS = 200 mV / 10.0 A = 20 mΩ.
The resistance value should be selected to maximize the input bandwidth use of the coulomb<br>counter range, CCRANGE, but not exceed the absolute maximum ratings.<br>• Using the normal max discharge current, RSNS = 200 mV / 10.0 A = 20 mΩ.