Components must be rotated and inspected at a distance of 45-60 cm (18-24 inches) or arm’s length for approximately 5 seconds per viewing side. If no defect is observed at the viewing distance, thecomponent should be considered acceptable without searching for a reason to reject. If a defect isidentified at this viewing distance, it is then permissible to pull the component closer for furtherinspection.