In fact, if the methanation reactor is equipped with a catalyst activeat temperatures over 300 ◦C and is managed in isothermal condition, the WGS outlet gas stream requires a pre-heating step beforebeing fed to CO-SMET reactor. This increases the complexity of thesystem processing the hydrocarbon fuel to prepare the H2-rich gas.