Please provide details of the plug gage used to verify this feature, along with pictures. A go/no-gage can be an acceptable method of measurement, but this gage must be calibrated.The preferred method for checking a bolt hole is using a dial bore gage, using a setting ring.I do not see a validation signature from the Quality person who did the inspection. Who completed this documentation?Our customer will have to re-work this part. They will charge PSC for this work, and we will send these cost to QFYK for credit.