When a (sleepy) end device joins a coordinator, the association process is almost the same as the standard IEEE 802.15.4. (SeeUG235.02: Using Silicon Labs Connectwith IEEE 802.15.4 for a short description.) The only difference is the 500ms delay betweenassociation request and data request commands, as seen in the figure above.