November 18, 2019Station: FA Audio Tester Line 2Description: Sudden close and open of moving upper fixture onlyCause: Possible power reset or control board switching problem.Action: Check Power connection if loose (power connection is firm, no moving of upper fixture after wiggle/rotating of power connection)