The resonance running speed nE1 may be above or below the running speed calculated from Equation (6)because of stiffnesses which have not been included (the stiffness of shafts, bearings, housings, etc.) and asa result of damping. For reasons of safety, the resonance ratio in the main resonance range, NS, is defined bythe following upper limit.NS < N u1,15