Electro-Fenton pretreatment was carried out in a glass reactor connected to an electric generator ASF type 400/40.10. Two iron electrodes which were positioned approximately 2.5 cm apart from each other were used. The active surface area of electrodes was 0.16 dm2. Electrolysis experiments were operated in batch mode by treating 300 ml of raw WAS. The pH of WAS sample was adjusted to 3 by adding HCl solution (2N). Current density, reaction time, and H2O2 concentration were fixed, respectively, at 2.5 A/ dm2, 1 h, and 1.8 g/l as optimum conditions determined in previous study. During electrolysis treatment, continuous homogenization was maintained to avoid sedimentation of sample.The disintegration degree after sludge pretreatment was evaluated by determining VSS solubilisation. The solubilisation percentage was calculated according to this formula [5]:With VSSt0 as the VSS before treatment and VSStf as the VSS after treatment.