Salt Spray Environment Test – Place the units inside the Salt spray test chamber. Units should be powered on, batteries and battery doors must be installed. For flip/slider/rotator products, position the units so that the flip/slider/rotator is in open position and facing up as shown in figure 2 below. For candy bar phones, position the units so that it is facing up. Provide a minimum of 5 cm spacing between each unit, and place the units at a 30-degree angle so the saline condensation will drip away from the units. Ensure that the saline solution that drips away will not pool at the bottom of the unit. Avoid spraying salt fog directly into the units. Droplets of condensation water built up from the ceiling of the chamber should also be avoided. Set the chamber parameter and press “Start” to begin the two (2) hour salt spray dwel