Effects of Scale:Batch volume to chamber surface area ratio (V/SA) affects the dispersion rate. For high ratios (i.e. production mixers), batch slippage effects dominate and dispersion rate suffers. For low ratios (i.e. lab-scale mixers), dispersion rates are relatively higher.