6.3 The Tg of the material may be obtained from this test,which is similar to Method 2.4.24. It should be noted that theTg so obtained is a ‘‘first pass’’ value.6.4 A faster ramp rate will decrease the time to run, providesome greater distinction between materials, and provide acloser equivalence to the Thermal Stress test, 2.4.13.1.A rate of 100°C/minute [212° F/minute] is recommended forsuch determinations.