16.4 The charge and discharge cycles are then repeated for a minimum of two complete cycles of charge and discharge. The DUT is then subjected to an observation period per 6.5.16.5 At the conclusion of the observation period, the samples shall be subjected to the ″as received″ dielectric voltage withstand test in accordance with Section 18 if it anticipated that there has been deterioration of the insulation during the temperature test. The DUT shall be examined for signs of rupture and evidence of leakage.16.6 The manufacturer’s specified operating limits for cells/modules (voltage, current at specified temperatures) shall not be exceeded during the charging and discharging cycles. Temperatures measured on components shall not exceed their specifications. Temperatures measured on accessible surfaces shall not exceed allowed limits. See Table 16.1 and Table 16.2 for temperature limit tables. Additional non-compliant results during the temperature test are as noted below in (a) – (e). For additional information on non-complying results refer to Table 10.1.