Since then, however, developments in the steam boiler field have led to the necessity for feed treatment which has made a great contribution towards the elimination of blade de- posits. With once-through boilers the same purity is demanded of the boiler feedwater asof the initial steam, since practically all salts pass straight through the boiler and will otherwise be deposited in the turbine.