The requirement of 8.1 applies for all positions of the appliance when it is operated as in normal use, and after the removal of detachable parts.NOTE This excludes the use of screw-type fuses and screw-type miniature circuit breakers that are accessible without the aid of a tool.Lamps located behind a detachable cover are not removed, provided that the appliance can be isolated from the supply mains by means of a plug or an all-pole switch. However, during insertion or removal of lamps which are located behind a detachable cover, protection against contact with live parts of the lamp cap shall be ensured.'Test probe B and probe 18 of EN 61032 are applied with a force not exceeding 1 N, the appliance being in every possible position, except that appliances normally used on the foor and having a mass exceeding 40 kg are not tilted.Through openings, the test probe is applied to any depth that the probe will permit and is rotated or angled before, during and after insertion to any position. If the opening does not allow the entry of the probe, the force on the probe in the straight position is increased to 20 N when probe B is used or 10 N when probe 18 is used. If the probe then enters the opening, the test is repeated with the probe in the angled position. However when using test probe 18 the appliance shall be fully assembled as in normal use without any parts removed; parts that are intended to beremoved for user maintenance shall not be remove.It shall not be possible to touch live parts or live parts protected only by lacquer, enamel, ordinary paper, cotton, oxide film, beads, or sealing compound except self-hardening resins, with the probe.