When testing EN12983 for baking tray samples, we found that the coating at the handle position had not been tested, and the coating had already fallen off just by sticking it with adhesive tape. If the products were sold and used, this situation would easily lead to consumer complaints. We suggest that the factory provide me with samples again for testing. Please send us 2pc for each sample for further evaluation.