— internal resistances, peak power and OCV versus time from the four-weekly voltage controls at RT; — C/3 capacity versus cycling time at RT from the four-weekly C/3 capacity determination and at −10 °C from the eight-weekly C/3 capacity determination;— capacity fade versus cycling time. 7.10.4 Calculation example for cycle life test for high-power battery system Concerning the energy throughput, the resulting values are the following: Assumption: average speed of 60 km/h Roughly calculated by “300 V × I × t” and summing of all steps Energy output each 5-min cycle: 0,36 kW⋅h 5 km; Energy output each hour: 4,32 kW⋅h 60 km; Energy output each day (22 h operation): 95,04 kW⋅h 1 320 km; Energy output each week: 665,28 kW⋅h 9 240 km; Energy output every 6 weeks: 3 991,68 kW⋅h 55 440 km; Energy output every 12 weeks (1 848 h operation):7 983,36 kW⋅h 110 880 km.