1.Structural interaction of the transfer plate and upper shear wall has a significant effect on the behav- iour of a transfer plate–shear wall system. By recognizing this interaction effect, the in-plane axial forces and stresses in the transfer plate can be greatly reduced, compared to those without consid- eration of the interaction effect.