新建线路宜采用同塔双回架空架设。在线路走廊特别紧张地区,可建设同塔多回架空线路(含混压)。在角钢塔无法架设的狭窄路段,线路可采用钢管杆架设。的英语翻译

新建线路宜采用同塔双回架空架设。在线路走廊特别紧张地区,可建设同塔多回

新建线路宜采用同塔双回架空架设。在线路走廊特别紧张地区,可建设同塔多回架空线路(含混压)。在角钢塔无法架设的狭窄路段,线路可采用钢管杆架设。市区电缆线路路径应与城市其他地下管线统一安排。通道的宽度、深度应考虑远期发展的要求。电缆的敷设应考虑安全、维护便利及节省投资等要求。电缆敷设方式应结合电压等级,最终回路数,施工条件及初期投资等因素确定,可按不同情况采取相应的敷设方式[13]。输电线路路径方案的选择应本着统筹规划、相互协调的基本原则,并按下述具体原则确定:
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
Newly-built lines should adopt double-circuit overhead erection on the same tower. In areas where the line corridors are particularly tight, multiple overhead lines (including mixed pressure) can be built on the same tower. In narrow sections where angle steel towers cannot be erected, the lines can be erected with steel pipe poles. <br>The cable route in the urban area should be arranged uniformly with other underground pipelines in the city. The width and depth of the passage should consider the requirements of long-term development. The laying of cables should consider the requirements of safety, convenient maintenance and saving investment. The cable laying method should be determined based on the voltage level, the final number of circuits, construction conditions and initial investment and other factors, and the corresponding laying methods can be adopted according to different situations [13]. <br>The selection of the transmission line path plan should be based on the basic principles of overall planning and mutual coordination, and be determined according to the following specific principles:
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
The new line should be set up with the same tower double back overhead. In areas where the route corridor is particularly tense, the same tower can be constructed with the Tower back overhead line (including mixed pressure). In narrow sections where the corner steel tower cannot be erected, the line may be set up with a steel pipe rod.<br>The urban cable line path should be arranged uniformly with other underground pipelines in the city. The width and depth of the channel should take into account the requirements of long-term development. Cable laying should take into account safety, maintenance convenience and investment savings. Cable laying method should be combined with voltage level, the final number of circuits, construction conditions and initial investment and other factors to determine, according to different circumstances can be adopted the corresponding laying method.<br>The choice of transmission line path scheme should be based on the basic principles of overall planning and coordination, and be determined by the following specific principles:
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
The new lines should be erected overhead with double circuits on the same tower. In areas where the line corridor is particularly tight, multi circuit overhead lines (including mixed voltage) on the same tower can be built. In the narrow section where the angle steel tower cannot be erected, the line can be erected with steel pipe pole.<br>The urban cable route should be arranged with other underground pipelines in the city. The width and depth of the passage should consider the requirements of long-term development. The cable laying should consider the requirements of safety, convenient maintenance and saving investment. The cable laying method should be determined by combining the voltage level, the number of final circuits, construction conditions and initial investment, and corresponding laying methods can be adopted according to different situations [13].<br>The selection of transmission line route scheme should be based on the basic principles of overall planning and mutual coordination, and determined according to the following specific principles:<br>
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.

Copyright ©2024 I Love Translation. All reserved.

E-mail: