In addition, if applicable, the 1C, 2C and the maximum permitted C rate shall be performed for capacity determination to meet the high-energy system requirements. Discharge shall be terminated on supplier specified discharge voltage limits depending on discharge rates and temperature. This test applies to battery packs and systems. 7.1.2 Test procedures7.1.2.1 High-power battery pack and system The test shall be performed at RT with the discharge rates of 1 C, 10 C and the maximum C rate as permitted by the supplier (the maximum C rate corresponds to Id,max). The test sequence shall be performed as specified in Table 1. Table 1 — Test sequence energy and capacity test at RT for high-power battery packs and systems