6.5.2 Lead Termination Requirements Component leads in through-hole connections may be terminated using a straight through, partially clinched, orclinched configuration. The clinch should be sufficient to provide mechanical restraint during the soldering process. The orientation ofthe clinch relative to any conductor is optional. DIP leads should have at least two diagonally opposing leads partially bent outward.Tempered leads shall not (D1 D2 D3) be terminated with a (full) clinched configuration.Tempered leads shall not (NoRqtEst.1 D2 D3) be trimmed unless specified on the drawings.Lead protrusion shall not (D1 D2 D3) violate minimum electrical clearance requirements. Lead protrusion shall (NoRqtEst.1 P2 D3)be in accordance with Table 6-3.Connector leads are exempt from the maximum length requirement provided that they do not violate minimum electrical spacing atthe next higher assembly level.