a) No evidence of major visual defects permitted, as defined in IEC 61215-1:2021, particularly looking for signs of melted solder, openings in the enclosure, delaminations and burn spots. If there is evidence of serious damage that does not qualify as a major visual defect, repeat the test on two additional cells within the same module. If there is no visual damage around either of these two cells the module type passes the hot-spot test. b) Verify that the module shows the electrical characteristics of a functional photovoltaic device. MQT 02 is not a pass/fail requirement (Gate No 2) for power loss. c) Insulation resistance shall meet the same requirements as for the initial measurements. d) Wet leakage current shall meet the same requirements as for the initial measurements. e) Any damage resulting from determining the worst case shadowing shall be noted in the test report.