630MW low-pressure cylinder to a turbine flow after upgrading province as the research object, by a slight increase of output test were obtained Backpressure on the relationship of the unit heat rate, output, and the exhaust volume flow and low-pressure cylinder the efficiency curve, the operating characteristics explore low-pressure cylinder; statistically significant operating data for the full year 2019 unit, to obtain the average load rate and the average back pressure data, in order to exhaust extrapolated annual average volume flow, results show under the above conditions, the low-pressure region to work effectively in the cylinder; the same type of horizontal comparison parameters, different length low pressure cylinder steam turbine last stage blade, the two units of the binding data transformation performance evaluation test of 50% THA, the comparison result further confirmed that the low-pressure cylinder unit has better operating characteristics contribute to wide-load operation of the economy in the face of the depth peaking.