Supplementary information:File recovery after under-frequency transient:Test Sequence B, P=0%Psmax, inverter DC input power is set to 0% of maximum active output power first (set the SOC funcation that the battery no discharge). After the inverter step into frequency range under 49.8Hz, the inverter available input power is set to 100% of maximum active output.