• Measurement dwell/scan times listed in CISPR 25 Table 1 and Table 2 shall be increased if the DUT operates with intermittent duration to capture the maximum level of emissions, and they shall be defined in the test plan and documented in the test report.• On DUTs with one or more connector, the harness attached to each connector shall be tested separately. If the DUT wiring has too many wires to be accommodated in the measurement probe, the test plan may define the wires to be measured and this shall be included in the test report.In addition to this, the power supply and power return wires (if exists) shall be measured separately and individually.• Measure the emissions with the probe positioned 50 mm and 750 mm from the DUT connectors. Other position, due to the dimension limitations in the setup, can be used with the approval of CEVT EMC department.• The DUT shall conform to each defined requirement, i.e., at frequencies where more than one detector is specified, all requirements apply simultaneously.