The durability test shall consist of 5,000 mating cycles of insertion and extraction with the mated plug .rate 500±50cycles per hour, no load condition, without lubric . The performance of the specimens before andafter this test shouldcomply with paragraphs 2-2 and 3-3. Reference to EIA-364-09.