2.4L型干湿结合消雾冷却塔运行控制消雾塔冷却水温的调控步序为:1) 全关湿冷段百叶窗,全开干冷段百叶窗,开启风机,循环水通过换热管束冷却后的英语翻译

2.4L型干湿结合消雾冷却塔运行控制消雾塔冷却水温的调控步序为:1)

2.4L型干湿结合消雾冷却塔运行控制消雾塔冷却水温的调控步序为:1) 全关湿冷段百叶窗,全开干冷段百叶窗,开启风机,循环水通过换热管束冷却后通过喷淋层直接进入水池。2) 随环境温度继续升高的调控为:逐步打开湿冷段百叶窗,当湿冷段百叶窗全开时,逐步关闭干冷段百叶窗,当干冷段百叶窗全关时,此时达到冷却塔的最大冷却能力。
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
The 2.4L type dry-wet combination cooling tower operation controls <br>the cooling water temperature control steps of the cooling tower as follows: <br>1) Fully close the shutters of the wet cooling section, fully open the shutters of the dry cooling section, turn on the fan, and the circulating water passes through the heat exchange tube bundle to cool and then passes through the spray The shower layer goes directly into the pool. <br>2) As the ambient temperature continues to rise, the regulation is as follows: gradually open the louvers in the wet-cooling section, and gradually close the louvers in the dry-cooling section when the louvers in the wet-cooling section are fully opened. When the louvers in the dry-cooling section are fully closed, the maximum cooling capacity of the cooling tower is reached.
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
Operation control of 2.4L type dry wet combined defogging cooling tower<br>The control steps for the cooling water temperature of the mist removal tower are as follows:<br>1) Fully close the wet cooling section louvers, fully open the dry cooling section louvers, and turn on the fan. The circulating water is cooled through the heat exchange tube bundle and then directly enters the water tank through the spray layer.<br>2) The regulation as the ambient temperature continues to rise is to gradually open the wet cooling section louvers. When the wet cooling section louvers are fully open, gradually close the dry cooling section louvers. When the dry cooling section louvers are fully closed, the maximum cooling capacity of the cooling tower is reached.
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
Operation control of 2.4L dry-wet demisting cooling tower<br> The control sequence of cooling water temperature of demister is as follows:<br> 1) Fully close the shutters of wet and cold section, fully open the shutters of dry and cold section, and turn on the fan. After cooling through the heat exchange tube bundle, the circulating water directly enters the pool through the spray layer.<br> 2) As the ambient temperature continues to rise, the regulation is as follows: gradually open the shutters in the wet and cold section, gradually close the shutters in the dry and cold section when the shutters in the wet and cold section are fully opened, and reach the maximum cooling capacity of the cooling tower when the shutters in the dry and cold section are fully closed.
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.

Copyright ©2024 I Love Translation. All reserved.

E-mail: