— internal resistances, peak power and OCV versus time from the four-weekly voltage controls at RT; — C/3 capacity versus cycling time at RT from the four-weekly C/3 capacity determination and at −10 °C from the eight-weekly C/3 capacity determination;— capacity fade versus cycling time. 7.10.4 Calculation example for cycle life test for high-power battery system Concerning the energy throughput, the resulting values are the following: Assumption: average speed of 60 km/h Roughly calculated by “300 V × I × t” and summing of all steps Energy output each 5-min cycle: 0,36 kW⋅h 5 km; Energy output each hour: 4,32 kW⋅h 60 km; Energy output each day (22 h operation): 95,04 kW⋅h 1 320 km; Energy output each week: 665,28 kW⋅h 9 240 km; Energy output every 6 weeks: 3 991,68 kW⋅h 55 440 km; Energy output every 12 weeks (1 848 h operation):7 983,36 kW⋅h 110 880 km.
-内部电阻,峰值功率和OCV相对于来自在室温下将四每周电压控制时间; <br>- C / 3容量对在RT从四每周C / 3容量确定和在-10℃从八每周C / 3容量确定循环时间; <br>-容量衰减与循环时间。<br>用于高功率电池系统循环寿命测试7.10.4计算例<br>关于能量通量,所得到的值如下:<br>假设:的60公里每小时平均速度<br>由“300 V×I×t”和求和的粗略计算所有步骤<br>能源输出的每个5分钟的周期:0,36kW⋅h5公里; <br>能源输出的每个小时:4,32kW⋅h60公里; <br>能量输出的每一天(22小时操作):95,04kW⋅h1320公里;<br>每星期能量输出:665,28kW⋅h9240公里; <br>能源输出每6周:3 991,68kW⋅h55440公里; <br>能量输出每12周(1个848小时连续操作):7 983,36kW⋅h110880公里。
正在翻译中..
-内阻,峰值功率和OCV对时间从四周电压控制在RT;<br>-C/3容量与四周C/3容量测定的RT和八周C/3容量测定的-10°C下的循环时间的关系;<br>-容量衰减与循环时间。<br>7.10.4大功率电池系统循环寿命试验计算实例<br>关于能量吞吐量,结果值如下:<br>假设:平均速度60km/h<br>按“300V×I×t”及各步骤之和粗略计算<br>每5分钟循环的能量输出:0,36 kW⋅h 5 km;<br>每小时输出能量:4,32千瓦⋅小时60公里;<br>每天发电量(22小时运行):95,04千瓦时1320公里;<br>每周发电量:665,28千瓦时9240公里;<br>每6周发电量:3991,68kw⋅h55440km;<br>每12周发电量(1848小时运行):7983,36千瓦时110 880公里。<br>
正在翻译中..