When critical error is reported in above signal, only commands towards open direction shall besent (see REQPROD 384153: Opening and Closing request and command clarification on how tohandle commands) as long as error is reported in above signal.- If a critical error is reported when curtain is at bottom parked position (fully open), the curtainwill stay there and continue to report back fully open.- If a critical error is reported when curtain is at top parked position (fully closed), the curtain willmove towards fully open at next switch activation towards open. This will be handled by thecurtain control ECU itself, the position feedback will be reported as fully open when curtain isassumed to have reached fully open.- If a critical error is reported while ongoing movement of curtain, the curtain will automaticallyreverse or continue towards fully open. This will be handled by the curtain control ECU itself, theposition feedback will be reported as fully open when curtain is assumed to have reached fullyopen.